Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24.246
Filter
1.
Kardiologiia ; 64(3): 40-45, 2024 Mar 31.
Article in Russian, English | MEDLINE | ID: mdl-38597761

ABSTRACT

AIM: Comparative analysis of the height of atherosclerotic plaques (AP) in the descending thoracic aorta (TA) according to two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE), and contrast-enhanced multislice computed tomography (MSCT). MATERIAL AND METHODS: The TA was examined using 2D, 3D TEE and contrast-enhanced MSCT in 34 patients (20 men and 14 women aged 68 [62; 71] years). AP heights were compared using the Bland-Altman method and the Spearman correlation analysis. This was a blinded comparative study which assessed the AP morphometry using each of the radiation modalities without knowing the results of the method being compared. RESULTS: 100 APs were examined in the descending TA. The mean height of all analyzed APs in the descending TA was 2.2 mm [2; 2.7] for 2D TEE, 3.1 mm [2.7; 3.55] for 3D TEE, and 3.05 mm [2.55; 3.55] for MSCT. The AP heights measured with 2D TEE was statistically significantly smaller than the heights of similar APs measured either with 3D TEE or MSCT. The mean difference (bias) was 0.88±0.34 mm between 2D and 3D TEE, and 0.83±0.41 mm between 2D TEE and MSCT. The correlation coefficients for the AP heights were r=0.87 (p<0.001) between 2D and 3D TEE and r=0.86 (p<0.001) between 2D TEE and MSCT. There were no differences in the height of similar APs between 3D TEE and MSCT. CONCLUSION: The three-dimensional reconstruction of AP in the TA by TEE is more accurate for quantitative assessment of AP than a two-dimensional study.


Subject(s)
Echocardiography, Three-Dimensional , Plaque, Atherosclerotic , Male , Humans , Female , Aorta, Thoracic/diagnostic imaging , Plaque, Atherosclerotic/diagnostic imaging , Echocardiography , Echocardiography, Transesophageal
2.
West J Emerg Med ; 25(2): 166-174, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38596913

ABSTRACT

Introduction: Intra-arrest transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) have been introduced in adult patients with cardiac arrest (CA). Whether the diagnostic performance of TTE or TEE is superior during resuscitation is unclear. We conducted a systematic review following PRISMA guidelines. Methods: We searched databases from PubMed, Embase, and Google Scholar and evaluated articles with intra-arrest TTE and TEE in adult patients with non-traumatic CA. Two authors independently screened and selected articles for inclusion; they then dual-extracted study characteristics and target conditions (pericardial effusion, aortic dissection, pulmonary embolism, myocardial infarction, hypovolemia, left ventricular dysfunction, and sonographic cardiac activity). We performed quality assessment using the Quality Assessment of Diagnostic Accuracy Studies Version 2 criteria. Results: A total of 27 studies were included: 14 studies with 2,145 patients assessed TTE; and 16 with 556 patients assessed TEE. A high risk of bias or applicability concerns in at least one domain was present in 20 studies (74%). Both TTE and TEE found positive findings in nearly one-half of the patients. The etiology of CA was identified in 13% (271/2,145), and intervention was performed in 38% (102/271) of patients in the TTE group. In patients who received TEE, the etiology was identified in 43% (239/556), and intervention was performed in 28% (68/239). In the TEE group, a higher incidence regarding the etiology of CA was observed, particularly for those with aortic dissection. However, the outcome of those with aortic dissection in the TEE group was poor. Conclusion: While TEE could identify more causes of CA than TTE, sonographic cardiac activity was reported much more in the TTE group. The impact of TTE and TEE on the return of spontaneous circulation and further survival was still inconclusive in the current dataset.


Subject(s)
Aortic Dissection , Ventricular Dysfunction, Left , Adult , Humans , Echocardiography , Echocardiography, Transesophageal , Resuscitation , Aortic Dissection/diagnostic imaging
3.
Ann Card Anaesth ; 27(2): 159-161, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38607880

ABSTRACT

ABSTRACT: The elephant trunk procedure, an endovascular strategy for retrograde type A acute aortic dissection, is associated with several complications, hemolytic anemia being a rare one. We performed endovascular stent-graft insertion in a patient who developed hemolytic anemia. Transesophageal echocardiography (TEE) detected turbulent jet flow and stenosis position, which was not detected by angiography and intravascular ultrasound (IVUS). This imaging technique proved effective for malperfusion diagnosis and enabled us to confirm its resolution after the endovascular procedure. Intraoperative TEE is a useful adjunct to angiography and IVUS for diagnosis and therapeutic assessment during endovascular repair of a stenosed elephant trunk.


Subject(s)
Anemia, Hemolytic , Aortic Dissection , Humans , Echocardiography, Transesophageal , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Echocardiography , Angiography , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Constriction, Pathologic
4.
Am J Case Rep ; 25: e943042, 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38627956

ABSTRACT

BACKGROUND A paradoxical air embolism (PAE) occurs when air entering the central venous circulation reaches the systemic circulation, occurring through an intracardiac shunt or intrapulmonary shunting. Patients presenting for liver transplantation often have intrapulmonary shunting due to pulmonary arterial vasodilation, even in the absence of hepatopulmonary syndrome. Here, we present a case of hemodynamic collapse believed to be caused by a PAE, which was diagnosed intraoperatively with transesophageal echocardiography (TEE). CASE REPORT A 60-year-old man who was diagnosed with non-alcoholic steatohepatitis cirrhosis presented for deceased donor orthotopic liver transplantation with utilization of normothermic machine perfusion. Following reperfusion of the liver allograft, TEE detected intrapulmonary shunting resulting in air within the left atrium, left ventricle, and ascending aorta. The patient developed severe biventricular dysfunction with ST-segment changes on electrocardiography monitoring and became acutely hypotensive with significant hepatic congestion 5 min after liver reperfusion. High doses of inotropic and vasopressor support were used as well as inhaled nitric oxide. The patient recovered after 30 min of medical management. The liver transplantation operation was successfully completed and the patient was discharged home on postoperative day 7. CONCLUSIONS Intracardiac air at the time of reperfusion during liver transplantation can originate from the donor allograft and result in PAE in the setting of intrapulmonary shunting. PAE can result in intracoronary air and should be considered in cases of hemodynamic instability in liver transplantation, especially if air is seen within the left atrium, left ventricle, and ascending aorta.


Subject(s)
Embolism, Air , Liver Transplantation , Male , Humans , Middle Aged , Liver Transplantation/adverse effects , Embolism, Air/etiology , Liver Cirrhosis/complications , Echocardiography, Transesophageal
6.
Praxis (Bern 1994) ; 113(3): 78-82, 2024 Mar.
Article in German | MEDLINE | ID: mdl-38655734

ABSTRACT

INTRODUCTION: Ischaemic stroke results from a sudden interruption of cerebral blood flow, often caused by thrombosis, embolism or hypoperfusion. Rarely, cardiac tumours are the cause of an embolic event. We report on an 80-year-old woman with a cerebral stroke. Successful thrombectomy revealed a histopathologically confirmed papillary fibroelastoma as the embolic source. Although it was not detectable on initial echocardiography, the tumour was discovered by transesophageal echocardiography. This case emphasises the importance of considering primary cardiac tumours as potential sources of emboli in ischaemic stroke. Keywords.


Subject(s)
Echocardiography, Transesophageal , Heart Neoplasms , Humans , Female , Aged, 80 and over , Heart Neoplasms/diagnostic imaging , Heart Neoplasms/surgery , Heart Neoplasms/pathology , Diagnosis, Differential , Thrombectomy , Ischemic Stroke/diagnostic imaging , Ischemic Stroke/etiology , Ischemic Stroke/surgery , Fibroma/surgery , Fibroma/diagnostic imaging , Fibroma/pathology
7.
Sci Rep ; 14(1): 9295, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38653743

ABSTRACT

The prognosis of patients with embolic stroke of undetermined source (ESUS) may vary according to the underlying cause. Therefore, we aimed to divide ESUS into subtypes and assess the long-term outcomes. Consecutive patients with acute ischemic stroke who underwent a comprehensive workup, including transesophageal echocardiography and prolonged electrocardiography monitoring, were enrolled. We classified ESUS into minor cardioembolic (CE) ESUS, arteriogenic ESUS, two or more causes ESUS, and no cause ESUS. Arteriogenic ESUS was sub-classified into complex aortic plaque (CAP) ESUS and non-stenotic (< 50%) relevant artery plaque (NAP) ESUS. A total of 775 patients were enrolled. During 1286 ± 748 days follow-up, 116 major adverse cardiovascular events (MACE) occurred (4.2 events/100 patient-years). Among the ESUS subtypes, CAP ESUS was associated with the highest MACE frequency (9.7/100 patient-years, p = 0.021). Cox regression analyses showed that CAP ESUS was associated with MACE (hazard ratio 2.466, 95% confidence interval 1.305-4.660) and any stroke recurrence (hazard ratio 2.470, 95% confidence interval, 1.108-5.508). The prognosis of ESUS varies according to the subtype, with CAP ESUS having the worst prognosis. Categorizing ESUS into subtypes could improve patient care and refine clinical trials.


Subject(s)
Embolic Stroke , Humans , Male , Female , Embolic Stroke/etiology , Aged , Middle Aged , Prognosis , Echocardiography, Transesophageal , Risk Factors , Ischemic Stroke/etiology , Plaque, Atherosclerotic/complications , Plaque, Atherosclerotic/diagnostic imaging , Follow-Up Studies
8.
Int Heart J ; 65(2): 367-370, 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38479845

ABSTRACT

Papillary fibroelastoma (PFE) is a benign tumor that arises mostly from left-sided valves. PFE can cause stroke, and surgical resection may be needed. Lambl's excrescence (LE) is a filiform valvular lesion and is considered a possible cause of stroke. A 79-year-old man with light-headedness and left-sided hemiparesis was diagnosed with stroke. Transesophageal echocardiography (TEE) revealed a round-shaped mobile mass in the left ventricular outflow tract (LVOT), which was considered the cause of the stroke. Surgical resection was performed transaortically, and during surgery, a mass was incidentally detected on the noncoronary cusp (NCC), which was also resected followed by aortic valve replacement. Pathology confirmed that the mass in the LVOT was a PFE and that the filiform mass on the NCC was LE. We herein report a rare case of PFE in the LVOT and coexisting LE on the NCC. A careful examination via TEE helps to identify other possible causes of stroke hidden behind the obvious cause.


Subject(s)
Cardiac Papillary Fibroelastoma , Heart Neoplasms , Heart Valve Diseases , Stroke , Male , Humans , Aged , Heart Valve Diseases/complications , Cardiac Papillary Fibroelastoma/complications , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/pathology , Stroke/complications , Echocardiography, Transesophageal , Heart Neoplasms/diagnosis , Heart Neoplasms/diagnostic imaging
9.
Echocardiography ; 41(3): e15785, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38527004

ABSTRACT

BACKGROUND: Trans-catheter mitral valve replacement (TMVR) procedures had emerged as an alternative solution for patients who are at high risk for mitral valve surgery. Although cardiac computed tomography (CT) remains the standard method for procedural planning, there is no full agreement on the best systolic phase for quantitation of the neoLVOT. Furthermore, a new three-dimensional trans-esophageal echocardiography (3DTEE) based software was developed to serve as filter and or an alternative for patients who cannot have CT due to any contraindication. AIM: To determine the systolic phase of the cardiac cycle that shows the narrowest NeoLVOT area in order to standardize the way of using these software and then to validate the 3DTEE-based software against the CT-based one as a gold standard, in mitral valve annulus (MA) and NeoLVOT assessment. METHODS: A single center, observational, retrospective study. Initially, a sample of 20 patients (age 62 ± 4 years, 70% men) had CT-based analysis at mid-diastole (80%), early-systole (10%), mid-systole (20%), late-systole (30%-40%), in order to detect the best systolic phase at which the neoLVOT area is the narrowest after TMVR. Then, the end systolic phase was standardized for the analysis of 49 patients (age 57 ± 6 years, 60% men), using both the commercially available CT-based software and the newly available 3DTEE-based software (3mensio Structural Heart, Pie Medical Imaging, The Netherlands). The 3DTEE derived parameters were compared with the gold standard CT-based measurements. RESULTS: The neoLVOT area was significantly narrower at end-systole (224 ± 62 mm2), compared to early-systole (299 ± 70 mm2) and mid-systole (261 ± 75 mm2), (p = .005). Excellent correlation was found between 3DTEE and CT measurements for MA AP diameter (r = .96), IC diameter (r = .92), MA area (r = .96), MA perimeter (r = .94) and NeoLVOT area (r = .96), (all p-values < .0001). Virtual valve sizing was based on annulus measurement and was identical between CT and 3DTEE. Interobserver and intraobserver agreements were excellent for all the measurements with ICCs > .80. CONCLUSIONS: End-systole is the phase that shows the narrowest neoLVOT and hence should be the standard phase used during the analysis. The 3DTEE based analysis using this new software is reliable compared to the CT-based analysis and can be serve as an alternative analysis tool in patients who cannot have CT for any clinical contraindication or as a screening test and/or filter for all patients before proceeding to a detailed CT scan.


Subject(s)
Echocardiography, Three-Dimensional , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aged , Female , Humans , Male , Middle Aged , Catheters , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Heart Valve Prosthesis Implantation/methods , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Reference Standards , Reproducibility of Results , Retrospective Studies
10.
Catheter Cardiovasc Interv ; 103(5): 741-750, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38451154

ABSTRACT

BACKGROUND: The GCA is a well performing device in terms of efficacy despite complex anatomies (aortic rim <5 mm and ASD diameter >17 mm) with a good safety profile. AIMS: To evaluate atrial septal defect (ASD) features impacting on right disc device thrombosis in patients who underwent Gore Cardioform ASD Occluder (GCA) implantation. METHODS: A total of 44 consecutive patients undergoing percutaneous ASD with GCA device from January 2020 to September 2022 at our tertiary care Center were evaluated. The minimum follow-up was 6 months. RESULTS: The patients were stratified in two groups according to a cut-off value of ASD diameter equal to 20 mm at sizing balloon, derived from ROC analysis (AUC = 0.894; p = 0.024). Baseline characteristics were comparable between groups in terms of age, sex, weight, height, and interatrial septum dimensions. Patients with ASD > 20 mm (n = 9) had a higher ASD/device dimension ratio, both at echocardiography (p = 0.009) and at sizing balloon (p = 0.001), longer fluoroscopic time (p = 0.022), and higher incidence of device thrombosis (0.006). Right disc thrombosis was observed in three patients of the ASD > 20 mm group, always in the inferior portion of the right disc. On univariate analysis, ASD diameter at sizing balloon (OR 1.360; p = 0.036) was the only positive predictor of device thrombosis. CONCLUSIONS: Right disc thrombosis of the GCA device may be under-recognized at follow-up, hence deserving clinical attention, especially in those patients with larger ASD diameters.


Subject(s)
Heart Septal Defects, Atrial , Septal Occluder Device , Humans , Echocardiography, Transesophageal , Treatment Outcome , Cardiac Catheterization/adverse effects , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/therapy
11.
J Cardiovasc Med (Hagerstown) ; 25(4): 311-317, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38488065

ABSTRACT

AIMS: We present the experience and long-term results of intracardiac echocardiography (ICE)-guided closure of ostium secundum atrial septal defects (ASDs) in two Italian centers and investigate its systematic applicability as the gold standard in routine clinical practice. METHODS: We retrospectively evaluated all consecutive patients who underwent an ASD percutaneous closure procedure from March 2008 to February 2020. All patients underwent a preprocedural transesophageal echocardiography (TEE) evaluation. The closures were carried out under fluoroscopic and ICE guidance. A follow-up visit was performed at 1, 3 and 12 months, followed by telephone evaluations approximately every 2 years. RESULTS: Sixty-six patients (29% male individuals), mean age 43 ±â€Š16 years, were treated. In 15 cases, the TEE defect diameter was less than 10 mm, and in 8 of these patients, the ICE intraprocedural sizing increased the maximum diameter by more than 5 mm. Sizing balloon of the defect was performed in 51 cases; 2 patients received an ASD 38 mm device. Eight patients had multiple defects; in three of these, it was necessary to apply two devices. Four patients showed nonsignificant residual shunt; no complications related to the use of ICE were observed. One patient presented the migration of the ASD device into the abdominal aorta, percutaneously retrieved with a snare. No major complications were recorded during the entire follow-up period. CONCLUSION: This study confirms that ICE monitoring during ASD percutaneous closure is well tolerated and effective; it might be achievable as a routine gold standard by operators willing to use ICE systematically in all transcatheter closure interventions of interatrial communications.


Subject(s)
Cardiac Catheterization , Heart Septal Defects, Atrial , Humans , Male , Adult , Middle Aged , Female , Retrospective Studies , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/therapy , Echocardiography, Transesophageal , Fluoroscopy , Treatment Outcome
12.
Echocardiography ; 41(3): e15798, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38516863

ABSTRACT

Editing of 3D raw images acquired during transesophageal echocardiography could be similar to the post processing of raw images with digital software used in photography. 3D image editing in echocardiography is often underestimated in clinical practice, and people are satisfied with the first 3D image they are able to obtain during transesophageal examination. In fact, it is often believed to represent solely an aesthetic addition that does not change the information already obtained with 2D and baseline 3D. In reality, it represents a crucial moment to better understand the mechanisms of mitral pathology, avoiding artifacts and misjudgments. The importance of acquiring raw 3D images of the valve having all the necessary information (ring, the leaflet in toto, the right frame rate) allows us then to edit them making them more beautiful and clearer from the point of view of the information received. Nevertheless, by exclusively acquiring a raw 3D with all the necessary information, we can quickly finish the transesophageal examination, reducing its duration and discomfort for the patient, as well as the inherent risk of complications related to the procedure per se.


Subject(s)
Echocardiography, Three-Dimensional , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Echocardiography/methods , Echocardiography, Transesophageal/methods , Photography
13.
Echocardiography ; 41(3): e15799, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38516862

ABSTRACT

Atherosclerosis is the most common cause of heart disease and stroke. Plaque thickness ≥4 mm in the ascending aorta or aortic arch is strongly correlated with cerebral embolic events and ischemic stroke. However, despite imaging workup, the cause of embolic stroke remains unidentified in many patients. Transesophageal echocardiography (TEE) is the preferred echocardiographic method for the evaluation of cardiac source of emboli. 2D TEE imaging evaluates aortic root and aortic arch in a single plane or two planes with biplane imaging. However, 2D TEE often fails to detect mobile or complex components in the ascending aorta and aortic arch plaques. The routine availability of 3D TEE in current ultrasound systems may significantly improve the assessment of aortic plaques as a potential embolic source. In this case series, we present four consecutive patients with stroke who underwent TEE by a single cardiologist for possible cardioembolic source. Some of these patients may have been labelled as "cryptogenic stroke" or "embolic stroke of undetermined source" (ESUS) due to the presence of insignificant or nonmobile ascending aortic or aortic arch plaques on 2D TEE imaging. In our four consecutive patients with ESUS who underwent TEE by a single operator, 3D TEE showed complex aortic arch plaques with ulceration with mobile components and established these plaques as the likely source of embolic stroke.


Subject(s)
Aortic Diseases , Atherosclerosis , Embolic Stroke , Embolism , Plaque, Atherosclerotic , Stroke , Humans , Plaque, Atherosclerotic/complications , Plaque, Atherosclerotic/diagnostic imaging , Echocardiography, Transesophageal/methods , Embolic Stroke/complications , Atherosclerosis/complications , Atherosclerosis/diagnostic imaging , Stroke/complications , Stroke/diagnostic imaging , Aorta, Thoracic/diagnostic imaging , Embolism/complications , Aortic Diseases/complications , Aortic Diseases/diagnostic imaging
16.
Sci Rep ; 14(1): 5860, 2024 03 11.
Article in English | MEDLINE | ID: mdl-38467726

ABSTRACT

Atrial fibrillation (AF) is the most common human arrhythmia, forming thrombi mostly in the left atrial appendage (LAA). However, the relation between LAA morphology, blood patterns and clot formation is not yet fully understood. Furthermore, the impact of anatomical structures like the pulmonary veins (PVs) have not been thoroughly studied due to data acquisition difficulties. In-silico studies with flow simulations provide a detailed analysis of blood flow patterns under different boundary conditions, but a limited number of cases have been reported in the literature. To address these gaps, we investigated the influence of PVs on LA blood flow patterns and thrombus formation risk through computational fluid dynamics simulations conducted on a sizeable cohort of 130 patients, establishing the largest cohort of patient-specific LA fluid simulations reported to date. The investigation encompassed an in-depth analysis of several parameters, including pulmonary vein orientation (e.g., angles) and configuration (e.g., number), LAA and LA volumes as well as their ratio, flow, and mass-less particles. Our findings highlight the total number of particles within the LAA as a key parameter for distinguishing between the thrombus and non-thrombus groups. Moreover, the angles between the different PVs play an important role to determine the flow going inside the LAA and consequently the risk of thrombus formation. The alignment between the LAA and the main direction of the left superior pulmonary vein, or the position of the right pulmonary vein when it exhibits greater inclination, had an impact to distinguish the control group vs. the thrombus group. These insights shed light on the intricate relationship between PV configuration, LAA morphology, and thrombus formation, underscoring the importance of comprehensive blood flow pattern analyses.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Pulmonary Veins , Thrombosis , Humans , Atrial Appendage/diagnostic imaging , Pulmonary Veins/diagnostic imaging , Echocardiography, Transesophageal , Heart Atria/diagnostic imaging , Atrial Fibrillation/diagnostic imaging
17.
Kardiol Pol ; 82(3): 303-307, 2024.
Article in English | MEDLINE | ID: mdl-38493455

ABSTRACT

BACKGROUND: The correlation between atrial septum anatomy and the risk of ischemic neurological events remains underexplored. AIMS: This study aimed to examine both the functional and anatomical attributes of the atrial septum and identify predictors of stroke and/or transient ischemic attack (TIA) in patients diagnosed with patent foramen ovale (PFO). METHODS: A total of 155 patients diagnosed with PFO, with a cardiological cause of neurological events, were enrolled. Transesophageal echocardiography was utilized to assess the anatomy of the PFO canal, size of the right-to-left shunt, thickness of the primary and secondary atrial septum, presence of atrial septum aneurysm, and anatomical structures of the right atrium. RESULTS: Regression analysis showed that factors such as female sex, hypercholesterolemia, PFO canal width, and a large right-to-left shunt were significantly associated with stroke and/or TIA. Receiver operating characteristic analysis indicated that the width of the PFO canal holds a relatively weak, although significant predictive, value for ischemic neurological episodes (area under the curve = 0.7; P = 0.002). A PFO canal width of 4 mm was associated with 70% sensitivity and 55% specificity for predicting stroke and/or TIA. CONCLUSIONS: The atrial septum's anatomy, especially the dimensions of the PFO canal and the magnitude of the right-to-left shunt, combined with specific demographic and clinical factors, are linked to ischemic neurological incidents in PFO patients.


Subject(s)
Atrial Septum , Foramen Ovale, Patent , Ischemic Attack, Transient , Stroke , Humans , Female , Foramen Ovale, Patent/complications , Foramen Ovale, Patent/diagnostic imaging , Atrial Septum/diagnostic imaging , Ischemic Attack, Transient/etiology , Ischemic Attack, Transient/complications , Stroke/etiology , Stroke/complications , Heart Atria/diagnostic imaging , Echocardiography, Transesophageal/adverse effects
18.
J Cardiothorac Surg ; 19(1): 139, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38504295

ABSTRACT

BACKGROUND: Left atrial dissection (LAtD) is a rare but potentially life-threatening complication of mitral valve surgery. Its management is not well stablished in the literature. However, early recognition through intraoperative TEE and attention to changes in the left atrial free wall during saline leak testing can lead to avoidance of severe complications. CASE PRESENTATION: We report a case of LAtD detected by intraoperative transesophageal echocardiogram (TEE) following mitral valve repair for primary mitral valve regurgitation secondary to degenerative mitral valve disease with MAZE IV procedure for atrial fibrillation. LAtD was noted on TEE as an expanding double density along the wall of the left atrium with a jet originating at the posterior annulus flowing into the LAtD which was repaired. Separation from bypass following LAtD repair was complicated by severe biventricular dysfunction requiring significant inotropic support and placement of an intra-aortic balloon pump (IABP). Patient's post-operative course was further complicated by right sided heart failure requiring placement of a right sided impella which was subsequently removed on POD 4. Patient was discharged home on POD 17. Transthoracic echo at 1 month, 3 months demonstrated resolution of the LAtD. A follow up echo at 4 years showed complete resolution of the LAtD with an intact mitral repair, trace mitral regurgitation, and a mean gradient across the repair of 3 mm Hg. CONCLUSIONS: Left atrial dissection is a rare but serious complication of mitral valve surgery. We provide a review of the current literature regarding LAtD, emphasizing the need to consider this complication early during mitral surgery to allow for uncomplicated repair.


Subject(s)
Atrial Fibrillation , Cardiac Surgical Procedures , Mitral Valve Insufficiency , Humans , Heart Atria/surgery , Heart Atria/diagnostic imaging , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Echocardiography, Transesophageal , Atrial Fibrillation/complications
19.
J Cardiothorac Surg ; 19(1): 137, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38504353

ABSTRACT

BACKGROUND: Paradoxical embolism is a rare cause of acute arterial occlusion. This phenomenon arises when embolic material travels from the venous system crosses an abnormal shunt such as patent foramen ovale, atrial septal defects, ventricular septal defects, or pulmonary arteriovenous malformations, into the arterial system. Impending paradoxical embolism refers to the presence of an entrapped thrombus in the patent foramen ovale. CASE PRESENTATION: We report a case of a 68-year-old female patient who presented with an impending paradoxical embolism, alongside both concomitant pulmonary embolism and myocardial infarction with ST-segment elevation. Swiftly addressed through emergency cardiac surgery and systemic anticoagulation, the patient's condition was effectively treated. CONCLUSIONS: While the ideal treatment strategy for impending paradoxical embolism remains a topic of debate due to limited and inconclusive evidence, emergent open surgery should be contemplated in patients as it signifies a critical clinical emergency.


Subject(s)
Embolism, Paradoxical , Foramen Ovale, Patent , Myocardial Infarction , Pulmonary Embolism , Female , Humans , Aged , Foramen Ovale, Patent/complications , Foramen Ovale, Patent/surgery , Embolism, Paradoxical/complications , Embolism, Paradoxical/surgery , Echocardiography, Transesophageal , Pulmonary Embolism/complications , Pulmonary Embolism/surgery , Myocardial Infarction/complications , Myocardial Infarction/surgery
SELECTION OF CITATIONS